Insulating Glass Units (IGUs)

Enhanced thermal and acoustic comfort for your spaces. Two glass panes separated by a sealed, dry air space, custom-made to meet the requirements of each project.

Discover Insulating Glass

Two Glass Panes, One Integrated Solution

An insulating glass unit (IGU) consists of two glass panes separated by a sealed, dry air space. A perimeter spacer and sealing system maintain the integrity of the unit.

This composition reduces heat transfer between indoor and outdoor environments, helping improve thermal comfort. Depending on the glass configuration, IGUs can also enhance sound insulation and provide additional safety and solar control benefits.

At Extralum, we manufacture custom insulating glass units, tailoring each configuration to the specific requirements of residential, commercial, and architectural projects.

Video (in Spanish): What Is an Insulating Glass Unit and What Are Its Benefits? Watch on YouTube

Simplified diagram of an insulating glass unit showing the exterior glass pane, interior glass pane, dry air space, perimeter spacer, and edge seal.

Features and Benefits

Greater Comfort in Every Space

Improved Thermal Insulation

The sealed air space reduces heat transfer between indoor and outdoor environments, helping maintain more comfortable interior temperatures compared to single glazing.

Greater Comfort Near Windows

IGUs help reduce uncomfortable temperature differences near glazed surfaces. Under certain conditions, they can also reduce the likelihood of condensation forming on the interior glass surface.

Reduced Outdoor Noise

Depending on their configuration, IGUs can improve sound insulation, particularly when combining glass panes of different thicknesses or laminated glass with acoustic properties.

Versatile Configurations

IGUs can incorporate different glass types, including solar control and low-emissivity (Low-E) glass, as well as FUERTEX® tempered glass and VILAX® laminated glass, based on project requirements.

Thermal and acoustic performance depend on the glass configuration, cavity dimensions, and the characteristics of the complete glazing system.

Configurations

An IGU Designed for Every Project

Every space has different requirements. At Extralum, we manufacture insulating glass units in a variety of configurations, allowing you to select the glass types and air space dimensions that best meet your needs for thermal insulation, solar control, safety, and acoustic comfort.

What Can Be Customized?

Exterior Glass PaneClear, tinted, solar control, or safety glass.
Air SpaceSpacer width selected according to thermal performance and manufacturing requirements.
Interior Glass PaneClear glass, FUERTEX®, VILAX®, or other compatible glass options.
Glass CoatingsAppropriate positioning of Low-E or solar control coatings to achieve the desired performance.

Glass composition, thicknesses, coating positions, and overall dimensions must be determined according to the technical requirements of each project. The two glass panes do not necessarily need to have the same thickness.

1234ExteriorInteriorAir space

Glass Surface Identification

Surface 1
Exterior-facing surface of the outer glass pane.
Surface 2
Cavity-facing surface of the outer glass pane.
Surface 3
Cavity-facing surface of the inner glass pane.
Surface 4
Interior-facing surface of the inner glass pane.
Glass surfaces are numbered from the exterior to the interior. Coating placement depends on the glass type and application, as detailed in technical sheet IT-014.
IT-014 · Reflective Coating Placement (in Spanish)

Applications

Greater Comfort Across Different Spaces

Insulating glass units can be incorporated into compatible window, door, and facade systems for residential, commercial, and institutional projects. The selected systems must accommodate the dimensions, thickness, weight, and performance requirements of each unit.

Woman standing beside a large window in a contemporary home

Homes

Bedrooms, living rooms, and home offices where greater thermal and acoustic comfort is desired.

Woman working in an office with a large window overlooking the city

Offices

Workspaces with large glazed areas that benefit from improved thermal comfort and noise reduction.

Modern building featuring extensive glass windows

Hotels and Institutions

Hotels, hospitals, schools, and other facilities where indoor comfort and noise control are important.

Torre Universal office building with a glass curtain wall in Sabana, San José

Architectural Facades

Glazing solutions for commercial and corporate buildings with compatible facade systems, including projects such as Torre Universal in Sabana, San José. View Project (in Spanish)

Information for Professionals

Technical Considerations for Specifying IGUs

Selecting an insulating glass unit requires evaluating its thermal and acoustic performance, the characteristics of its components, and the conditions under which it will be installed.

Thermal Performance

  • U-Value (Thermal Transmittance): Measures the rate of heat transfer through the glazing. A lower U-value indicates better thermal insulation.
  • Shading Coefficient (SC): Compares the solar heat gain through a glazing configuration with that of a reference clear glass. A lower value indicates less solar heat gain.
  • Where performance data for the specific glass configuration is available, the evaluation should also consider the Solar Heat Gain Coefficient (SHGC) and Visible Light Transmittance (VLT).

Acoustic Performance

  • Sound insulation depends primarily on the glass composition, individual pane thicknesses, interlayers, and the performance of the complete window or facade system.
  • Within typical IGU cavity widths, increasing the air space alone generally provides limited acoustic benefits. Glass mass, asymmetric pane thicknesses, and the use of laminated glass can have a greater influence on noise reduction.
  • For reference, technical sheet IT-041 provides recommended maximum indoor noise levels for different spaces, including:
    • Bedrooms: 30–40 dB
    • General Offices: 45–50 dB
  • These values refer to recommended indoor ambient noise levels, not the sound insulation ratings of an IGU. The appropriate glazing configuration must be determined based on the acoustic requirements of each project.

Pressure Equalization With Capillary Tubes

Significant differences in altitude between the manufacturing location and the installation site can create changes in atmospheric pressure that affect the integrity of an insulating glass unit.

According to Extralum technical instruction IT-051, a pressure-equalizing capillary tube is required when the altitude difference exceeds 600 m, including situations where this difference occurs during transportation.

Once the unit reaches its final destination, it must be allowed to equalize with the local atmospheric pressure for 24 hours.

After pressure equalization, the capillary tube must be properly closed and sealed following the established technical procedure to maintain the integrity of the unit.

IT-051 · Capillary Tubes for IGUs (in Spanish)

Condensation

Understanding Condensation on Insulating Glass

Condensation occurs when humid air comes into contact with a surface whose temperature is below the dew point.

On insulating glass units, condensation can occur on different glass surfaces. Its location helps determine whether it is a normal environmental condition or a potential sign of seal failure.

Room-facing surface

On the Interior Surface

Usually associated with indoor humidity levels and the temperature of the glass surface.

Improving ventilation and controlling indoor humidity can help reduce condensation.

Exterior-facing surface

On the Exterior Surface

Can occur under certain weather conditions, including on high-performance insulating glass units.

Exterior condensation alone does not indicate a product defect.

Inside the air space

Between the Glass Panes

Moisture or condensation inside the sealed air space may indicate a failure of the perimeter seal.

In these cases, a technical evaluation is necessary, and the insulating glass unit may need to be replaced.

IT-064 · Condensation in Insulating Glass Units (in Spanish)

Technical Resources

Technical Information for Every Project

Access technical documents to better understand the performance, installation requirements, and maintenance considerations of Extralum insulating glass units.

Sales and Technical Support

Looking to Improve Comfort in Your Project?

At Extralum, we help you identify the insulating glass unit configuration best suited to your thermal insulation, noise reduction, and safety requirements.

Tell us about your project, and our team will guide you through the available options to help you choose the right solution.